SAMP_MODE=00, OSC_DIV=00
RNG Miscellaneous Control Register
| SAMP_MODE | Sample Mode 0 (00): use Von Neumann data into both Entropy shifter and Statistical Checker 1 (01): use raw data into both Entropy shifter and Statistical Checker 2 (10): use Von Neumann data into Entropy shifter. Use raw data into Statistical Checker |
| OSC_DIV | Oscillator Divide 0 (00): use ring oscillator with no divide 1 (01): use ring oscillator divided-by-2 2 (10): use ring oscillator divided-by-4 3 (11): use ring oscillator divided-by-8 |
| UNUSED | This bit is unused but write-able. Must be left as zero. |
| TRNG_ACC | TRNG Access Mode |
| RST_DEF | Reset Defaults |
| FOR_SCLK | Force System Clock |
| FCT_FAIL | Read only: Frequency Count Fail |
| FCT_VAL | Read only: Frequency Count Valid. Indicates that a valid frequency count may be read from FRQCNT. |
| ENT_VAL | Read only: Entropy Valid |
| TST_OUT | Read only: Test point inside ring oscillator. |
| ERR | Read: Error status |
| TSTOP_OK | TRNG_OK_TO_STOP |
| PRGM | Programming Mode Select |